Explored CVE-2024-0769: vulnerability in D-Link DIR-859 HTTP POST Request. Learn impact and prevention strategies.
This CVE-2024-0769 article provides detailed information about a vulnerability discovered in D-Link DIR-859 HTTP POST Request hedwig.cgi path traversal.
Understanding CVE-2024-0769
The vulnerability identified as CVE-2024-0769 affects D-Link DIR-859 version 1.06B01 and involves a critical issue related to path traversal in the HTTP POST Request Handler component.
What is CVE-2024-0769?
A critical vulnerability has been identified in D-Link DIR-859 version 1.06B01, specifically related to the file /hedwig.cgi in the HTTP POST Request Handler component. Exploiting this vulnerability involves manipulating the service argument with specific input that results in path traversal. The attack can be initiated remotely, making it a serious concern. This vulnerability has been assigned the identifier VDB-251666.
The Impact of CVE-2024-0769
The exploitation of this vulnerability can lead to unauthorized access to sensitive files on the affected system, posing a significant security risk. It has been rated as critical due to the potential consequences of a successful attack.
Technical Details of CVE-2024-0769
The following technical details outline the vulnerability, affected systems, and exploitation mechanism associated with CVE-2024-0769.
Vulnerability Description
The vulnerability in D-Link DIR-859 version 1.06B01 allows for path traversal through manipulation of the service argument in the /hedwig.cgi file within the HTTP POST Request Handler component. This manipulation can enable attackers to access files outside the intended directory structure.
Affected Systems and Versions
The vulnerability impacts D-Link DIR-859 version 1.06B01. It is essential for users of this specific version to take immediate action to secure their systems.
Exploitation Mechanism
By manipulating the service argument with a specific input containing directory traversal characters, attackers can bypass security measures and access critical system files. This can lead to unauthorized data exposure and potential system compromise.
Mitigation and Prevention
To mitigate the risks associated with CVE-2024-0769, users and organizations should take the following steps to enhance their security posture.
Immediate Steps to Take
Long-Term Security Practices
Patching and Updates
Stay informed about security advisories and updates released by D-Link for vulnerabilities such as CVE-2024-0769. Timely patching of systems is crucial to safeguard against known threats and maintain a secure environment.