Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2023-33919 : Exploit Details and Defense Strategies

Learn about CVE-2023-33919, a critical vulnerability in Siemens CP-8031 and CP-8050 modules allowing remote code execution. Find mitigation steps and best security practices here.

A vulnerability has been identified in CP-8031 MASTER MODULE and CP-8050 MASTER MODULE by Siemens due to missing server-side input sanitation, allowing for command injection. This could lead to an authenticated attacker executing arbitrary code with root privileges.

Understanding CVE-2023-33919

This section will provide insights into the nature and impact of the CVE-2023-33919 vulnerability.

What is CVE-2023-33919?

The CVE-2023-33919 vulnerability exists in the web interface of CP-8031 MASTER MODULE and CP-8050 MASTER MODULE devices, enabling an attacker to execute malicious commands with elevated permissions.

The Impact of CVE-2023-33919

The impact of this vulnerability is severe as it grants an authenticated attacker the ability to run arbitrary code with root privileges, potentially leading to system compromise and unauthorized access.

Technical Details of CVE-2023-33919

In this section, we will delve into the specific technical aspects of the CVE-2023-33919 vulnerability.

Vulnerability Description

The vulnerability arises from the lack of proper input sanitization in the web interface of the affected devices, making them susceptible to command injection attacks.

Affected Systems and Versions

The affected systems include CP-8031 MASTER MODULE and CP-8050 MASTER MODULE with versions older than CPCI85 V05.

Exploitation Mechanism

An authenticated privileged remote attacker can exploit this vulnerability by injecting malicious commands via the web interface, potentially leading to the execution of arbitrary code with root privileges.

Mitigation and Prevention

This section offers guidance on how to mitigate the risks associated with CVE-2023-33919 and prevent potential exploitation.

Immediate Steps to Take

Immediately update the affected devices to version CPCI85 V05 or newer to mitigate the vulnerability. Restrict access to the web interface to authorized and trusted users only.

Long-Term Security Practices

Implement regular security training for personnel to raise awareness about cyber threats and best security practices. Consider deploying network monitoring solutions to detect and prevent unauthorized access.

Patching and Updates

Stay informed about security updates and patches released by Siemens for the CP-8031 MASTER MODULE and CP-8050 MASTER MODULE devices. Promptly apply relevant patches to ensure the security of the devices.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now