Discover the details of CVE-2021-27399 affecting Siemens' Simcenter Femap versions 2020.2 and 2021.1. Learn about the impact, technical description, affected systems, and mitigation steps.

A vulnerability has been identified in Siemens' Simcenter Femap versions 2020.2 and 2021.1. The flaw exists in the femap.exe application due to improper validation of user-supplied data when parsing FEMAP files. This could lead to an out-of-bounds write vulnerability that an attacker could exploit to execute code within the current process context.

Understanding CVE-2021-27399

This section will cover the details of the CVE-2021-27399 vulnerability in Simcenter Femap.

What is CVE-2021-27399?

The vulnerability exists in Simcenter Femap versions 2020.2 (All versions < V2020.2.MP3) and 2021.1 (All versions < V2021.1.MP3) where the femap.exe application fails to properly validate user-supplied data during FEMAP file parsing. This flaw allows an attacker to trigger an out-of-bounds write beyond the allocated structure, potentially leading to code execution.

The Impact of CVE-2021-27399

Exploiting this vulnerability could enable an attacker to execute malicious code within the context of the current process, posing a severe security risk to affected systems.

Technical Details of CVE-2021-27399

Let's dive into the technical specifics of CVE-2021-27399 in Simcenter Femap.

Vulnerability Description

The vulnerability stems from the lack of proper validation in the femap.exe application during FEMAP file parsing, resulting in an out-of-bounds write issue.

Affected Systems and Versions

Simcenter Femap 2020.2 (All versions < V2020.2.MP3) and Simcenter Femap 2021.1 (All versions < V2021.1.MP3) are affected by this vulnerability.

Exploitation Mechanism

By providing specially crafted data to exploit the lack of input validation in FEMAP files, an attacker could execute arbitrary code within the process environment.

Mitigation and Prevention

Learn how to protect your systems from the CVE-2021-27399 vulnerability in Simcenter Femap.

Immediate Steps to Take

It is crucial to apply security updates provided by Siemens to patch the vulnerability and prevent potential exploitation.

Long-Term Security Practices

Implementing secure coding practices and regular security assessments can help mitigate similar vulnerabilities in the future.

Patching and Updates

Stay informed about security advisories and promptly apply patches and updates released by Siemens to address known vulnerabilities.