Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2018-12777 : Vulnerability Insights and Analysis

Learn about CVE-2018-12777, an Out-of-bounds read vulnerability in Adobe Acrobat and Reader versions 2018.011.20040 and earlier. Find out the impact, affected systems, and mitigation steps.

Adobe Acrobat and Reader versions 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier are affected by an Out-of-bounds read vulnerability that could lead to sensitive information disclosure.

Understanding CVE-2018-12777

An Out-of-bounds read vulnerability has been identified in Adobe Acrobat and Reader versions 2018.011.20040 and earlier, 2017.011.30080 and earlier, as well as 2015.006.30418 and earlier. If exploited, this vulnerability may result in the disclosure of sensitive information.

What is CVE-2018-12777?

CVE-2018-12777 is an Out-of-bounds read vulnerability in Adobe Acrobat and Reader versions that could allow attackers to access sensitive information.

The Impact of CVE-2018-12777

The vulnerability could potentially lead to the disclosure of sensitive data if successfully exploited by malicious actors.

Technical Details of CVE-2018-12777

Adobe Acrobat and Reader versions 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier are affected by this vulnerability.

Vulnerability Description

The vulnerability is classified as an Out-of-bounds read issue, which could allow unauthorized access to sensitive information.

Affected Systems and Versions

        Adobe Acrobat and Reader 2018.011.20040 and earlier
        Adobe Acrobat and Reader 2017.011.30080 and earlier
        Adobe Acrobat and Reader 2015.006.30418 and earlier

Exploitation Mechanism

The vulnerability could be exploited by attackers to read data beyond the bounds of the allocated memory, potentially leading to the exposure of sensitive information.

Mitigation and Prevention

It is crucial to take immediate steps to address and prevent the exploitation of CVE-2018-12777.

Immediate Steps to Take

        Update Adobe Acrobat and Reader to the latest patched versions.
        Monitor security advisories for any further updates or patches related to this vulnerability.

Long-Term Security Practices

        Regularly update software and applications to mitigate known vulnerabilities.
        Implement network security measures to detect and prevent unauthorized access.

Patching and Updates

        Apply security patches provided by Adobe to address the Out-of-bounds read vulnerability in affected versions.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now